Product Description
The Model 933 interfaces between a heating appliance (wood pellet or alternative fuel stove) and its AC wall outlet. When AC utility power is present, the Model 933 charges a battery and monitors the wall outlet to detect a power outage. At the moment utility power fails, the Model 933 draws energy from a battery and converts it to enable appliance operation. When utility power returns, the Model 933 automatically switches the appliance back to AC wall outlet power. At the same time, the Model 933 resumes charging the battery to return it to full capacity in preparation for the next power failure.
GENERAL APPLICATION
- To determine compatibility: User should verify that the heating appliance does not draw more than 10A continuously from the outlet.
APPLICATIONS
- Wood Pellet Stoves
- Refrigerators
- Kerosene Heaters
- Gas Stoves
- Corn Stoves
- Multi Fuel Stoves
ADVANTAGES
- Works with Most Alternative Fuel Devices
- Instant Automatic Power Transfer
- Supports Full Stove Electrical Capacity
- Does Not Occupy Living Quarter Space
- Can Be Easily Installed
- Silent and Clean Operation
Features
- Pure Sine Wave Inverter
- Rugged Aluminum Housing
- Battery Cables Included
- Works with Common Marine Batteries
- Compact Size
- For Wall Mount or Surface Mount Installation
- 2 year Factory Warranty
BATTERY TYPE
Only batteries conforming to Battery Council International (BCI) group size
27 or larger are recommended (up to size 31). INSTALL ONLY deep cycle
batteries. (wet cell or AGM type) The marine-variety is acceptable. DO NOT
use car batteries or lithium
Specifications
INPUT:
- AC:-
NOMINAL INPUT VOLTAGE RANGE 108-132 VAC
FREQUENCY 60 Hz.
BATTERY SYSTEM VOLTAGE 12 VDC - DC:-
MAXIMUM A-HR RATING OF BATTERY SYSTEM 300
OUTPUT:
- OUTPUT VOLTAGE NOMINAL 115-120 VAC Sine Wave Power
OUTPUT CURRENT MAXIMUM 10A
MAXIMUM CONTINUOUS OUTPUT POWER 1200 W
MAXIMUM CURRENT SURGE 25A for 3 seconds
PROTECTION:
- LOW BATTERY SHUTDOWN < 10.5 +/-0.3 VDC
OVERLOAD SHUTDOWN Set to shut off at 110% of maximum current
with continuous automatic retry
OVER TEMPERATURE SHUTDOWN Via internal thermostat, self resetting
COOLING By Convection and forced air
FUSING Customer access to output fuses
CONNECTIONS:
- INPUT CONNECTION 18/3 SJT Power cord
BATTERY CONNECTION via supplied #2 AWG cables (4 ft. long) via terminal blocks
AUDIO ALARM:
- LOW BATTERY Alarm sounds when the battery nears completely depleted
VISUAL LED INDICATORS:
- ACTIVE WHEN LIT On - Indicates that power is present at the output receptacle
BATTERY MONITOR Flashing - Battery Charging / On - Battery Fully Charged
REPLACE BATTERY On - Replace battery
MECHANICAL:
- MOUNTING SLOT CENTERS (in./cm.) 12.0 x 7.8 / 30.5 x 19.8
DIMENSIONS, (in./cm.) (L x W x H) 18.0 x 8.5 x 3.5 / 45.7 x 22 x 9 inch / cm.
HOUSING MATERIAL All Aluminum with steel end caps
WEIGHT, (lb./kg.) 18 / 8.2 : lbs/kg.